SmartLock Digital

Axessor
Comparison
Chart

One for every eventuality

Axessor CIT, USB and IP all share the common functions:

  • Lock inputs and outputs: 2 inputs (one switched, one potential 12V) 2 outputs switched
  • Local connection: USB
  • Event memory: > 10,000 entries
  • Languages : English, German, French, Italian, Spanish, Portuguese, Dutch, Hungarian, Polish and Turkish selectable
Axessor CIT
Axessor USB

AXESSOR CIT

One time codes
Yes

Network capable
Yes

Master codes
1, can / cannot open, Time lock interruption

Manager codes
4, changeable authorisation

User codes
36, four groups

Courier code
1, open or time delay override

Special code
One time codes for ICS and OTC, output pulse codes, Audit and time code, one shot code, locking and unlocking code

Dual mode
Yes, any two codes, same or different user group codes

First open dual
Yes

Weekly locking periods
35

Holiday locking periods
22

Time lock interruption
Yes, 8 programmable

Time delay
8, two per group

First open time delay extension
Yes

Time-dependent functions
3 for each group 1, 2 and 3

Non-return time delay
Yes

Selectable display for time delay counting
Yes

AXESSOR USB

One time codes
No

Network capable
No

Master codes
1, can / cannot open

Manager codes
2

User codes
18, two groups

Courier code
1

Special code
Audit and time code

Dual mode
Yes, any two codes

First open dual
No

Weekly locking periods
16

Holiday locking periods
22

Time lock interruption
No

Time delay
4, two per group

First open time delay extension
No

Time-dependent functions
No

Non-return time delay
No

Selectable display for time delay counting
No

AXESSOR IP

One time codes
No

Network capable
Yes

Master codes
1, can / cannot open, Time lock interruption

Manager codes
4, changeable authorisation

User codes
36, four groups

Courier code
1, open or time delay override

Special code
Output pulse codes, Audit and time code, one shot code, locking & unlocking code

Dual mode
Yes, any two codes, same or different user group codes

First open dual
No

Weekly locking periods
35

Holiday locking periods
22

Time lock interruption
Yes, 8 programmable

Time delay
8, two per group

First open time delay extension
No

Time-dependent functions
3 for each group 1, 2 and 3

Non-return time delay
Yes

Selectable display for time delay counting
Yes

With the Axessor series you define setup and functional range of your high security locking system.

SYDNEY • MELBOURNE • BRISBANE • PERTH • ADELAIDE • AUCKLAND